80
FA display Parameters
(
total 7
)
Code
Name
Setting Scope
Min Unit
Defaulted
Value
Address Change
FA.00
LED displayed parameter
selection 1
Binary set
:
0
:
No displaying
1
:
Displaying
LED Units
:
Bit0
:
Output
frequency(before
compensation,Hz)
Bit1
:
Output
frequency ( after
compensation,Hz)
Bit2
:
Setting
frequency(Hz blink)
Bit3
:
Output
current(A)
LED Tens
:
Bit0
:
Run
speed(RPM)
Bit1
:
Setting
speed(RPM)
Bit2
:
Reserved
Bit3
:
Reserved
LED Hundreds
:
Bit0
:
Output power
Bit1
:
Output torque
(
%
)
1
00D
A00H
○
FA01
LED displayed parameter
selection 2
Binary set
:
0
:
No Display
1
:
Display
LED Units
:
Bit0
:
Output
voltage(V)
Bit1
:
Barbus voltage
Bit2
:
Reserved
Bit3
:
AI(V)
LED Tens
:
Bit0
:
Analog
closeloop feedback (%)
Bit1
:
Analog
closeloop setting(%)
Bit2
:
External count
Bit3
:
Terminal state
LED Hundreds
:
Bit0
:
Reserved
Bit1
:
Setting
pressure
1
000
A01H
○