83
FD Group
:
Professional function parameters 2
(
total 31
)
Code
Name
Setting Scope
Min Unit
Defaulted
Value
Address Change
FD.00
Simple PLC mode
LED Units
:
PLC run
mode
0
:
no-action
1
:
Stop after ending
single running
2
:
keep the final value
when single running
ends
3
:
Continuous circulation
LED Tens
:
Start mode
0
:
Run from the first
stage
1
:
Continue to run from
stage frequency of the
break time
2
:
Continue to run from
run frequency of the
break time
LED Hundreds
:
Power
failure storage
0
:
No memery
1
:
Memery
LED Thousands
:
Select
the unit of stage time
0
:
Second
1
:
Minute
1
0000
D00H
×
FD.01
Stage 1 setting
LEDUnits
:
0
:
Select mulit frequency
1 (F8.00)
1
:
Frequnecy depends on
thefunction code of
F0.02
LED Tens
:
0
:
Forward
1
:
Reverse
2
:
Subject to run
command
1
00
D01H
○
FD.02
Stage 1 run time
0.0~6500 s(min)
0.1
20.0s
D02H
○