When the control mode is keypad or serial port or 3-wire terminal 1 and 2,
there is no RUN command at power on.
3
.
If there is a Stop command, the inverter will not start.
F9.34 Terminal filter time
Range
:
0.5~100.0ms
【
7.5ms
】
F9.35 Current count value
Range
:
0~65535
【
0
】
Terminal filter time: can increase P9.34 properly, improve the anti-interference ability
of the X input terminals.Terminal filter, the longer terminal action delay time
is longer.
The current count value: built-in counter for input pulse count, the value can
be modified on-line, this value can be saved when power off."
F9.36 Under-voltage point set
Range
:
75.0%
~
135.0%
【
90%
】
F9.37~F9.42 Reserved
Reserved
F9.43 PWM Model optimization Range
:
0000
~
0211H
【
0011
】
F9.44~F9.50 Reserved
Reserved
Figure 6-47 PWM model optimization mode selection
6.11 Display Control Parameters
(
FA
)
FA.00 LED displayed parameter
selection 1
Range
:
000
~
3FFH
【
00DH
】