92
Control word
(
bit
)
Value
Function
Description
0
Inching to stop the
forward run
Bit5
1
Inching to reverse
0
Inching
to
stop
reverse
Bit6
1
Allow acceleration/
deceleration
Reserved
0
Forbidden
for
acceleration/
deceleration
Bit7
1
Host
computer
control valid
The control word
sent by the current
FC is effective
0
Host
computer
control invalid
The control word
sent by the current
FC is invalid
Bit8
1
The
main
set
effective
Enable
the
main
setting
0
The main set is
invalid
Ban the main setting
Bit9
1
Failure
reset
effective
0
Failure
reset
is
invalid
Bit15~Bit10
000000B
Reserved
Note
:
Inching to run given (Bit4, Bit5) shall not be effective simultaneously with the
control word Bit0 ~ Bit2
!
The inverter status word 1 bits are defined as follows
:
Status word
(
bit
)
Value
Function
Remark
Bit0
1
Inverter operation
0
Inverter stop
Bit1
1
Inverter reverse
0
Inverter forward
Bit2
1
Reach main setting
0
Not reach main setting
Bit3
1
Allow commmunciation control
0
Ban commmunciation control
Bit7~4
0000B
Reserved