Figure 6-59 LED Displayed Parameter 1 Setting
FA.00 and FA.01 define the parameters that can bedisplayed by LED when
the inverter is operating.
If Bit is set at0, the parameter will not be displayed;
If Bit is set at 1, the parameter will be displayed.
As to the conversion of binary format to Hex format, please refer to Table
6-12. You may press key to scroll through the parameters.
FA.01 LED displayed parameter
selection 2
Range
:
000
~
3FFH
【
000H
】
Figure 6-60 LED Displayed Parameter 2 Setting
Figure 6-61 Terminal Status Indication
FA.02 Displayed parameter at
Range
:
0000
~
3FFFH
【
2001H
】
Thou
Hun
Ten
One
BIT
0
:
Output voltage
V
BIT
1
:
Bus voltage
V
BIT
2
:
Reserved
BIT
3
:
AI V
BIT
0
:
Analog close-loop
feedback
%
BIT
1
:
Analog
close-loop
setting
%
BIT
2
:
External
counting
value
BIT
3
:
Terminal status
BIT
0
:
Reserved
BIT
1
:
Reserved
BIT
0
:
Reserved
BIT
1
:
Reserved
BIT
2
:
Reserved
BIT
3
:
Reserved