Appendix E: CIP Objects
63 (70)
#
Name
Access
Type
Value
Comments
6
Interface
Control
Get/Set
Struct of:
Control Bits
WORD
-
Interface control bits
Forced
Interface
Speed
UINT
-
Speed at which the interface shall be
forced to operate. Returns ‘Object state
Conflict’ if auto-negotiation is enabled
7
Interface Type
Get
USINT
-
See table “Interface Type” below.
10
Interface Label
Get
SHORT_STRING
—
See table “Interface Label” below.
Interface Flags
Bit
Name
Description
0
Link status
Indicates whether or not the Ethernet 802.3 communications interface is
connected to an active network.
Value:
Meaning:
0
Inactive link
1
Active link
1
Half/full duplex
Indicates the duplex mode currently in use.
Value:
0
1
Meaning:
Half duplex
Full duplex
2 - 4
Negotiation Status
Indicates the status of link auto-negotiation.
Value:
Meaning:
0
Auto-negotiation in progress.
1
Auto-negotiation and speed detection failed (using default
values)
(Recommended default values are 10 Mbps, half duplex)
2
Auto negotiation failed but detected speed (using default duplex
value)
3
Successfully negotiated speed and duplex.
4
Auto-negotiation not attempted. Forced speed and duplex.
5
Manual Setting requires Reset
Value:
Meaning:
0
Interface can activate changes to link parameters during runtime
1
Reset is required in order for changes to have effect
6
Local Hardware Fault
Value:
Meaning:
0
No local hardware fault detected
1
Local hardware fault detected
7-31
(reserved)
Set to 0.
Interface Label
Instance
Value
1
Port 1
2
Port 2
3
Internal
Interface Type
Instance
Value
Description
1
2
Twisted-pair
2
2
Twisted-pair
3
1
Internal interface
Linking Device User Manual
scm-1202–181 2.0 en-US
Содержание Anybus HMS-EN2MB-R
Страница 1: ...Linking Device EtherNet IP to Modbus TCP USER MANUAL scm 1202 181 2 0 en US ENGLISH...
Страница 5: ...Linking Device User Manual scm 1202 181 2 0 en US H Copyright Notices 67...
Страница 6: ...This page intentionally left blank...
Страница 34: ...This page intentionally left blank...
Страница 64: ...Appendix E CIP Objects 62 70 Name Access Type Value Comments Linking Device User Manual scm 1202 181 2 0 en US...
Страница 71: ...This page intentionally left blank...