42
C22UE001-2004
Figure 3-8 Two-wire proximity switch wiring diagram
Pin 1 and pin 9 are used for 24V/1A signal, not for power
input of end effector.
The maximum output current at each pin is 100mA.
Two-wire proximity switch may cause Robot Input error
action occur due to residual voltage. Therefore, if you want
to use two-wire proximity switch, you should connect it
according to Figure 3-8 and select the matching R value.
Two-wire proximity switch
Two-wire proximity switch
Internal circuit
Internal circuit
Positive input
Negative input