11
C22UE001-2004
More attention should be paid to the pressure
remained in the pneumatic systems after the power
is disconnected.
The internal pressure must be released before the
pneumatic systems are maintained.
More attention should be paid to the pressure in the
pneumatic system as it is several times more than
the atmosphere pressure.
3.6 Emergency Stop Switch
The robot or other control component should have
at least one device for immediate halt, such as an
emergency stop switch.
The emergency stop button must be installed in an
easily accessible location for quick stop.
While executing an emergency stop, power to the
servo motor will be cut, and all movements will be
stopped. And the control system will be shut down.
Emergency stop should be reset if the restoration of
operating procedure is wanted.
Avoid using emergency stop to replace a normal
stop procedure. This could reduce the lifespan of the
robot.
The drive power and the control system will be
disconnected to stop all actions during the
emergency stop.
If you want to restart the procedures, you should
reset the emergency stop switch.
Emergency stop established an immediate stop:
Immediately stop the robot system, and disconnect
the driver power.
The emergency stop switch is used for emergency
stop only.
The
HIWIN
robot is equipped with two emergency
stop switches, where one is installed on the teach
pendant and the other is directly connected to the
controller via a cable. If additional emergency stop
switches are required, other connecting method can
Содержание RA605-710-GC
Страница 1: ...www hiwin tw User Manual Articulated Robot RA605 GC Original Instruction...
Страница 34: ...33 C22UE001 2004 Figure 2 3 b RA605 909 GC Motion range...
Страница 51: ...50 C22UE001 2004 5 3 Operation Name descriptions of the manual brake release device and their functions...
Страница 68: ...67 C22UE001 2004 8 Appendix Suspension plate refer to section 1 1...