Miscellaneous—Operational Checkout
– – –1/1
Monitor Circuit, Gauge
Checks
DISPLAY
SELECT
SET
WORKMODE
2
1
6
5
4
3
T141968
–UN–04MAY01
1—Engine Coolant Temperature Gauge
2—Fuel Gauge
3—Alternator Voltage Indicator
4—Engine Oil Pressure Indicator
5—Dig Mode Indicator
6—Monitor Display
Start engine.
Are all monitor indicator lights OFF after engine starts
except for the dig mode indicator (5)?
Is coolant temperature gauge needle (1) moving toward
normal operating zone after a few minutes?
Does fuel gauge (2) indicate fuel level?
Does monitor display (6) indicate machine hours are
changing?
YES:
Go to next check.
NO:
Check alternator belt
if alternator voltage
indicator lights after
engine starts, of ok, go to
your authorized dealer.
– – –1/1
Work Mode Circuit
Checks
SET
WORKMODE
3
2
1
T137610
–UN–02FEB01
1—Mode Selection Switch
2—Dig Mode Indicator
3—Attachment Mode Indicator
Auto-idle/auto-acceleration switch OFF.
Pilot shut-off lever in LOCKED position.
Push work mode selection switch (1) to select desired
work mode.
Do corresponding dig mode (2) or attachment mode (3)
indicators light as switch is pushed?
YES:
Go to next check.
NO:
Check fuse 1 in fuse
box, of ok, go to your
authorized dealer.
– – –1/1
Engine RPM Dial Checks
min-1
Slow Idle
1
T137611
–UN–05FEB01
1—Engine RPM Dial
Start engine.
Auto-idle/auto-acceleration switch OFF.
Move engine RPM dial (1) clockwise.
Does engine speed increase?
Move engine RPM dial counterclockwise.
Does engine speed decrease?
YES:
Go to next check.
NO:
Go to your
authorized dealer.
4-2-3
081407
PN=174
Содержание Zaxis 200LC
Страница 1: ...PART NO OMT200293 Operator s Manual 200LC 250 350 FORESTER ...
Страница 2: ......
Страница 5: ...Introduction TX14740 0001FA5 19 11DEC02 3 3 T124916 19 22FEB05 081407 PN 3 ...
Страница 6: ...Introduction 081407 PN 4 ...
Страница 253: ......
Страница 255: ...200LC 250 350 Operator s Manual OMT200293 ...