Maintenance—Every 2000 Hours
OUT1739,0000242
–19–05AUG02–1/1
Adjust Engine Valve Clearance
See your authorized dealer for engine valve clearance
adjustment.
NOTE: Perform this service at the first 500 hours of
operation and then at 2000 hour intervals
thereafter.
VD76477,0000172
–19–16JUN06–1/1
Replace High Pressure Supply Filter—Zaxis
200LC, Zaxis 250
T213350B
–UN–30AUG05
1—Filter Bowl
2—Drain Plug
3—Head Assembly
1. Turn off and depressurize the system.
2. Open drain plug (2) and drain oil into a suitable
container. Dispose of waste properly.
3. Turn filter bowl (1) counterclockwise and remove from
head assembly (3).
4. Remove filter element from inside of bowl and inspect
the surface for contamination.
5. Discard filter element.
6. Inspect filter head assembly and by-pass valve (3) for
damage. Replace as necessary.
7. Lubricate o-ring seal and install new filter element.
8. Ensure the threads of the filter bowl and head are
clean and dry.
9. Lightly lubricate the threads of the filter bowl and screw
the filter bowl on to the head assembly.
10. Close drain plug.
11. Bleed the system and check for leaks. (See Section
3-3).
3-11-5
081407
PN=149