Maintenance—As Required
OUT1739,0000218
–19–05AUG02–1/1
Clean Radiator Air Inlet Screen
T154565
–UN–03MAY02
1—Air Inlet Screen
Remove two wing nuts to slide screen up for cleaning.
TX14740,0001F8A
–19–06DEC02–1/1
Drain Water Separator
T147893B
–UN–15NOV01
1—Fuel Filter (water separator) Assembly
2—Sediment Bowl
1. Open right access door to access water separator (1).
2. Open drain valve (3) and press pump (2) to extract
water from fuel system. Collect waste in a container
and dispose of it properly.
3. Close drain valve.
4. Bleed fuel system.
3-3-2