Maintenance—Every 250 Hours
OUT4001,0000276
–19–12APR07–1/1
Inspect and Re-Torque Track Hardware
NOTE: Perform this service at 50 hours and at 250 hour
intervals thereafter.
See Inspect and Re-Torque Track Hardware. (Section
3-6.)
TX14740,0000073
–19–10AUG05–1/1
Clean Spark Arrester (If Equipped)
T193105A
–UN–11JUL03
1—Cleanout Plug
CAUTION: Prevent possible burning injury. DO
NOT touch any part of exhaust system until it is
cool.
1. Remove the cleanout plug (1) from the bottom of the
spark arrester (muffler) and allow waste to collect into
a container
2. Repeatedly tap on the arrester near the cleanout plug.
This may be enough to begin drainage of the spark
trap.
3. Enter cab and start engine.
4. Run engine for 2 minutes alternating between slow and
fast idle.
5. Stop engine and let exhaust system cool.
6. Install the cleanout plug.
7. Dispose of waste properly.
3-8-8
081407