Maintenance—Every 250 Hours
OUT1739,000022B
–19–05AUG02–1/3
Check Battery Electrolyte Level and
Terminals
TS203
–UN–23AUG88
CAUTION: Battery gas can explode. Keep
sparks and flames away from batteries. Use a
flashlight to check battery electrolyte level.
NEVER check battery charge by placing a metal
object across the posts. Use a voltmeter or
hydrometer.
ALWAYS remove grounded (-) battery clamp
first and replace it last.
Sulfuric acid in battery electrolyte is poisonous.
It is strong enough to burn skin, eat holes in
clothing, and cause blindness if splashed into
eyes.
Avoid the hazard by:
1. Filling batteries in a well-ventilated area.
2. Wearing eye protection and rubber gloves.
3. Avoiding breathing fumes when electrolyte is
added.
4. Avoiding spilling or dripping electrolyte.
5. Use proper jump start procedure.
If you spill acid on yourself:
1. Flush your skin with water.
2. Apply baking soda or lime to help neutralize
the acid.
3. Flush your eyes with water for 15—30
minutes. Get medical attention immediately.
If acid is swallowed:
1. Do not induce vomiting.
2. Drink large amounts of water or milk, but do
not exceed 1.9 L (2 quarts).
3. Get medical attention immediately.
1. Remove battery box cover.
3-8-4
081407
PN=128
Continued on next page
Содержание Zaxis 200LC
Страница 1: ...PART NO OMT200293 Operator s Manual 200LC 250 350 FORESTER ...
Страница 2: ......
Страница 5: ...Introduction TX14740 0001FA5 19 11DEC02 3 3 T124916 19 22FEB05 081407 PN 3 ...
Страница 6: ...Introduction 081407 PN 4 ...
Страница 253: ......
Страница 255: ...200LC 250 350 Operator s Manual OMT200293 ...