Maintenance—As Required
OUT1739,0000216
–19–05AUG02–1/1
Clean Fuel Tank Inlet Screen
T135186
–UN–06NOV00
1—Fuel Tank Inlet Screen
Clean screen (1) to remove any debris. Use solvent or
diesel fuel.
Replace screen if damaged.
OUT1739,0000217
–19–05AUG02–1/1
Drain Fuel Tank Sump
T6811AJ
–UN–18OCT88
T136406
–UN–18DEC00
1—Drain Valve
1. Park machine on a level surface. Rotate upperstructure
90
°
for easier access.
2. Stop engine.
3. Remove fuel tank fill cap.
NOTE: Some machines may be equipped with a pipe
plug in outlet fitting of drain valve. Remove this
pipe plug before opening drain valve.
4. Open drain valve (1) for several seconds to drain water
and sediment into a container. Dispose of waste
properly. Close drain valve.
5. Install fill cap.
3-3-1
081407
PN=109