282
14.5.3
Data Transfer Operations
SCI3 Initialization: Data transfer on SCI3 first of all requires that SCI3 be initialized as described
in 14.4.3, SCI3 Initialization, and shown in figure 14.5.
Transmitting: Figure 14.11 shows an example of a flowchart for data transmission. This
procedure should be followed for data transmission after initializing SCI3.
Start
End
Read bit TDRE
in SSR
1
2
Write transmit
data to TDR
Read bit TEND
in SSR
Clear bit TE to 0
in SCR3
No
TDRE = 1?
Yes
Continue data
transmission?
No
TEND = 1?
Yes
Yes
No
Read the serial status register (SSR) and
check that bit TDRE is set to 1, then write
transmit data to the transmit data register
(TDR). When data is written to TDR, bit
TDRE is cleared to 0 automatically, the
clock is output, and data transmission is
started.
When continuing data transmission, be
sure to read TDRE = 1 to confirm that
a write can be performed before writing
data to TDR. When data is written to
TDR, bit TDRE is cleared to 0 automatically.
1.
2.
Figure 14.11 Example of Data Transmission Flowchart (Synchronous Mode)