Recovery Time Limit specifies the time limit in 1ms increments, in which the
controller can execute the data error retrials.
The controller attempts the error recovery operation per command, within the
shorter time either of the Retry Count or the Recovery Time Limit.
There is the case that the time out is held pending until one operation finishes
even if the time out is detected after starting error recovery operation. In this
case, the actual time limit sometimes exceeds the time limit specified by the host
computer.
If the Recovery Time Limit is set to 0000
H
, the controller shall use its default
value.
If the Recovery Time Limit is set to FFFF
H
, the controller waits until the recovery
operation has terminated.
MODE SELECT:(15h)