OEM MANUAL:K6602771
6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19
Page: 139 / 313
Table 6-23 Supported Log Pages (cont’d)
11
0E
H
(Start-Stop cycle counter Page)
12
0F
H
(Application client Page)
13
10
H
(Self-Test Results Page)
14
2F
H
(Informational Exceptions Page)
15
3E
H
(Factory Log Page)
The page length field specifies the length in bytes of the following supported page
list. There is one byte for one page code ; therefore, the page length also indicates
the total number of log pages supported by the drive.
The supported page list field will contain a list of all log page codes implemented
by the drive in ascending order beginning with page code 00
H
.
Error Counter Log Pages (Page Code = 02
H
, 03
H
, 05
H
)
The formats of three supported error counter pages, read (page code 3
H
), write
(page 2
H
), and verify (page 5
H
), are the same. The error counter page for read
operation is defined in Table 6-24 to represent all three pages. A page can return
one or more error counters which record events defined by the parameter codes
(Table 6-25).
Table 6-24 Error Counter Read Page (Page Code = 3
H
)
Bit
Byte
7
6
5
4
3
2
1
0
0
Reserved
Page Code
0
0
0
0
0
0
1
1
1
Reserved
0
0
0
0
0
0
0
0
2
(MSB)
Page Length (n)
3
(LSB)
(cont’d)
LOG SELECT:(4Ch)