OEM MANUAL:K6602771
7 SENSE DATA
Revision: 2 / Date: 2002.12.19
Page: 295 / 313
7
SENSE DATA
The sense data is transferred to the host computer through the REQUEST SENSE
command (Refer to 6.23).
7.1
SENSE DATA FORMAT
This SCSI controller supports only the extended sense data format.
The extended sense data format is shown in Table 7-1.
The Error Code 70
H
(Current Error) or Error Code 71
H
(Deferred Error) are supported
by this controller.
Table 7-1 Extended Sense Data Format
Bit
Byte
7
6
5
4
3
2
1
0
0
Valid
Error Code
1
Segment Number
0
0
0
0
0
0
0
0
2
FileMark
EOM
ILI
R
Sense Key
0
0
0
3
Information Byte (MSB)
4
Information Byte
5
Information Byte
6
Information Byte (LSB)
7
Additional Sense Length
0
0
0
1
1
0
0
0
8-11
Command-Specific Information
12
Additional Sense Code
13
Additional Sense Code Qualifier
14
FRU Code
0
0
0
0
0
0
0
0