OEM MANUAL:K6602771
6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19
Page: 129 / 313
6.3
LOG SELECT:(4C
H
)
Bit
Byte
7
6
5
4
3
2
1
0
0
Operation Code (4C
H
)
0
1
0
0
1
1
0
0
1
Logical Unit Number
Reserved
PCR
SP
0
0
0
2
PC
Reserved
0
0
0
0
0
0
3
Reserved
0
0
0
0
0
0
0
0
4
Reserved
0
0
0
0
0
0
0
0
5
Reserved
0
0
0
0
0
0
0
0
6
Reserved
0
0
0
0
0
0
0
0
7
Parameter List Length (MSB)
8
Parameter List Length (LSB)
9
Vendor Unique
Reserved
Flag
Link
0
0
0
0
0
0
The LOG SELECT command provides a means for the initiator to manage statistical
information supported by the drive. The command descriptor block of LOG
SELECT provides for sending zero or more log pages during a DATA OUT phase.
The initiator can reset all the implemented log parameters to the drive-defined
default values by setting the PCR (parameter code reset) bit to one and the
parameter list length to zero. If PCR bit is one and the parameter list length is
greater than zero, the LOG SELECT command will be terminated with CHECK
CONDITION status. The sense key will be set to ILLEGAL REQUEST and the
sense code will be INVALID FIELD IN CDB. Table 6-16 shows all the setting
conditions.
Table 6-16 PCR and Parameter List Length Fields
PCR
Parameter List Length
Controller
’
s Action
1
Equal to 0
Reset all the implemented log parameters to
drive-defined default values
1
Greater than 0
Terminates with CHECK CONDITION status
0
Don
’
t care
Log parameters will not be reset
LOG SELECT:(4C
H
)