OEM MANUAL:K6602771
6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19
Page: 233 / 313
A Transfer Length of 0 specifies that no logical block is to be transferred. The
controller in this case only seeks to the track containing the block specified in the
Logical Block Address.
The controller terminates the command with a Check Condition status and with
the “Illegal Request” Sense Key if an invalid logical block address is specified (see
Note). For other errors, the controller terminates the command with the CHECK
CONDITION status and the appropriate sense key.
Note : The information byte field of the sense data is loaded with the last logical
block address.
READ (EXTENDED):(28h)