OEM MANUAL:K6602771
6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19
Page: 271 / 313
Enclosure Element Descriptor page
Enclosure Element Description page is used in order to report the description
(information) peculiar to a vender to each Elements.
Table 6-102 Enclosure Element Description page
Bit
Byte
7
6
5
4
3
2
1
0
0
Page Code = 07h
1
Reserved = 00h
2 –3
Page Length
4 – 7
Generation Code
8 – 11
Overall Descriptor (First Element Type)
12 – 15
Element Descriptor (First Element of First Element Type)
:
:
(4 bytes)
Element Descriptor (Last Element of First Element Type)
(4 bytes)
Overall Descriptor (Second Element Type)
(4 bytes)
Element Descriptor (First Element of Second Element Type)
:
:
(4 bytes)
Element Descriptor (Last Element of Last Element Type)
Short Enclosure Status page
Short Enclosure Status page is used when Enclosure Service Process does not
support other Enclosure Service page.
Table 6-103 Short Enclosure Status page
Bit
Byte
7
6
5
4
3
2
1
0
0
Page Code = 08h
1
8045
EFW
P_ESI-5
P_ESI-4
P_ESI-3
P_ESI-2
P_ESI-1
P_ESI-0
2 - 3
Page Length = 00h
When RECEIVE DIAGNOSTIC RESULTS command is received from Application
Client,the monitor result of EFW and P_ESI_0-5 are set as Byte 1 of Enclosure
Status page (4Bytes), and a controller reports them to Application Client.
When Enclosure Service Process is SFF-8045 support at bit 7 of Byte 1 at this
time, "1" is set, and "0" is set when it is SFF-8067.
SEND DIAGNOSTIC:(1Dh)