OEM MANUAL:K6602771
7 SENSE DATA
Revision: 2 / Date: 2002.12.19
Page: 306 / 313
2
35 02
Enclosure Services
Unavailable
Enclosure was SFF-8067 compliant
enclosure, but time out has occurred.
4
35 03
Enclosure Transfer
Failure
The time between the assertion of
– DSK_WR by the device and the assertion
of –ENCL_ACK by the enclosure exceeded
the device’s timeout.
4
35 04
Enclosure Transfer
Refused
The time between the assertion of the first
–DSK_WR and the first –ENCL_ACK of the
data transfer exceeded the device’s timeout.
1
37 00
Rounded Parameter A parameter value received was not useable
as it was, so it was rounded by the controller.
2
3E 00
Logical Unit Has
Not Self-configured
Yet
The Self-configuration of Logical Unit has
not finished yet.
4
3E 03
Logical Unit Failed
Self-Test
Failed to Self-Test.
4
3E 04
Logical Unit Unable
to Update Self-Test
Log
Unable to update the Self-Test log.
6
3F 00
Target Operating
Conditions Have
Changed
The operating conditions of target have
changed.
6
3F 01
Microcode Has
Been Changed
A micro code has been changed.
6
3F 02
Changed Operating
Definition
An operating definition has been changed.
6
3F 03
Inquiry Data Has
Changed
A Inquiry data has changed.
4
40 00
RAM Failure
Failure of RAM memory.
4
42 00
Power On or Self-
test Failure
A power-on diagnostic error occurred.
* MPU Error
* TIMER Error
* ROM Error
* Disk Controller Error
* ESDI H/W Error
* RAM Diagnostic Error
* Buffer Diagnostic Error
4
42 80
Hard Register Error
at Send Diag Self
Test
Hard register diagnostic error was detected
at Send Diag Self Test.
B
43 00
Message Error
The message was rejected and the operation
could not be continued.