OEM MANUAL:K6602771
6 COMMAND DESCRIPTIONS
Revision: 2 / Date: 2002.12.19
Page: 133 / 313
Table 6-20 Log Page Codes (cont’d)
07
H
Last n Error Events Page
08
H
- 0C
H
Reserved
0D
H
Temperature Page
0E
H
Start-Stop Cycle Counter Page
0F
H
Application Client Page
10
H
Self-Test Results Page
11
H
–
2E
H
Reserved
2F
H
Informational Exceptions Page
30
H
–
3D
H
Vendor Specific
3E
H
Factory Log Page
3F
H
Reserved
The page length field specifies the length in bytes of the following log parameters
that will be transferred between the initiator and the drive.
During a LOG SELECT command, if the initiator sends a page length that results
in the truncation of any parameter, the drive will terminate the command with
CHECK CONDITION status. The sense key will be set to ILLEGAL REQUEST
with the additional sense code set to INVALID FIELD IN PARAMETER LIST.
If the Log Page Code is set to 01
H
, 04
H
, or 08
H
-3F
H
, the controller creates the
CHECK CONDITION status with ILLEGAL REQUEST sense key.
[ Log Parameters ]
A log page may contain one or more log parameters (Table 6-21). Log parameters
may be data counters which record a count of a particular event(s) that
experienced by the drive or list parameters (strings) which contain a description of
a particular event.
Each log parameter (Table 6-21) begins with a four-byte parameter header
followed by one or more bytes of parameter value data.
Table 6-21 Log Parameter
Bit
Byte
7
6
5
4
3
2
1
0
0
(MSB)
Parameter Code
1
(LSB)
(cont
’
d)
LOG SELECT:(4Ch)