9.3 Canceling a Schedule
192
About operation restrictions while
[Reserved]
is displayed
(standby state)
• Keys related to starting, stopping, files, saving, and printing do not
work.
• To change a setting, first cancel the schedule. If you change a setting in
the standby state, a dialog box to confirm canceling the schedule oper-
ation will appear.
About schedule start and stop operations
• If the first schedule start time has passed at the point in time that the
schedule is set, the set measurement conditions are accessed and
measurement starts immediately.
• "The reservation will be started soon." is displayed 30 seconds before a
schedule start time, and then measurement starts at the start time.
• When repeat recording is set to
[Single]
, the schedule operation fin-
ishes when one measurement ends. When repeat recording is set to
[Repeat]
, measurement is performed repeatedly until the stop time.
• When the state is
[Waiting for pre-trigger]
or
[Waiting for trigger]
at
the stop time, measurement stops and the state switches to the waiting
for next schedule (schedule standby) state. When the state is [Storing],
measurement is halted, calculation, saving, and printing is performed
using the data up until that point in time, and then the state switches to
the next schedule standby state.
• If the next schedule start time has passed because of the time required
for saving and printing, the measurement conditions are accessed and
the next measurement starts immediately.
• When all schedules are complete, the scheduled state is cancelled.
• If the power is cut off when measurement is scheduled, the scheduled
state is resumed when the power recovers and measurement is started
if the time when the power recovers is between the schedule start time
and schedule stop time, regardless of the Start Backup setting (On/
Off).
• When the scheduled state is cancelled, the settings are restored to the
point in time that the schedule was enabled.
Содержание MR8880-20
Страница 2: ......
Страница 12: ...Procedure 2 ...
Страница 40: ...1 3 Screen Configuration and Display 30 ...
Страница 76: ...3 4 Measurement Using Setting Wizard PRESETS key 66 ...
Страница 174: ...6 4 Data Management 164 ...
Страница 186: ...7 7 Performing a Printer Check 176 ...
Страница 196: ...8 4 Numerical Value Calculation Expressions 186 ...
Страница 216: ...10 4 Making System Settings 206 ...
Страница 222: ...11 3 Communication Using Commands 212 4Click Next to start install ing Installing Click ...
Страница 226: ...11 3 Communication Using Commands 216 ...
Страница 254: ...13 6 Setting Wizard Function PRESETS 244 ...
Страница 292: ...Appendix 10 Installing Waveform Viewer A30 ...
Страница 297: ......
Страница 298: ......
Страница 299: ......
Страница 300: ......