55
Setting the Number of Loops (When Sweep Is Disabled)
7.7 Setting the Number of Loops (When Sweep Is
Disabled)
This section describes how to set the number of times to repeat the
arbitrary
waveform being output.
Once output starts, the waveform will be output the set number of times.
1
2
1
Select the
[Loop]
setting.
2
Press a function key (
F1
to
F5
) or select a button with the mouse.
Continues to repeat the arbitrary waveform until output is stopped.
Up-Down
p.18
Tenkey entry
p.19
Valid number of loops setting range: 1 to 50,000
After the waveform is output the set number of times, a 0 V signal will be output.
If the clock frequency, amplitude adjustment, or offset is set to sweep, the number of loops
setting cannot be con gured.
If a delay has been set, the repeat output waveform will be generated as follows:
2000 data points
Output settings
Delay: 500
Number of loops: 5
1st
2nd
3rd
4th
5th
Start of output
7
Arbitrary W
aveform Settings (U8793)
www.
.com
1.800.561.8187