ENGINE (J05E)/TROUBLESHOOTING
2–523
1.
Set the starter key to the "LOCK" position.
2.
Disconnect the EGR cooler outlet temperature sensor connector.
3.
Use the electrical tester to measure the resistance between the
terminals of the EGR cooler outlet temperature sensor.
NO
YES
1.
Set the starter key to the "ON" position.
2.
Use the electrical tester to measure the voltage between the termi-
nals of the EGR cooler outlet temperature sensor vehicle side con-
nector.
NO
YES
3
Inspect the EGR cooler outlet temperature sensor
THG
E2
SHTS021270300483
Measurement
conditions
Tester
connections
Standard values
Starter key: LOCK
EGR cooler outlet
temperature sen-
sor
THG
–
E2
50
C {122
F}:
7.4
–
19.6 k
100
C {212
F}:
3.0
–
6.2 k
150
C {302
F}:
1.5
–
2.6 k
Do the measurements meet the standard value?
Go to step 4.
Replace the EGR cooler outlet temperature
sensor.
Perform "After-inspection work" of INFOR-
MATION section.
4
Inspect the EGR cooler outlet temperature sensor power supply
E2
THG
SHTS021270300484
Measurement
conditions
Tester
connections
Standard values
Starter key: ON
EGR cooler outlet
temperature sen-
sor vehicle side
connector
THG
–
E2
4.5
–
5.5 V
Do the measurements meet the standard value?
Go to step 7.
Go to step 5.