ENGINE (J05E)/TROUBLESHOOTING
2–518
DTC: P041C and P041D
EN01H02127030602016079
P041C: EGR gas temperature sensor - out of range (Out of range low)
INFORMATION
1.
Technical description
•
The installed EGR cooler outlet temperature sensor consistently measures temperature at the outlet of the EGR
cooler.
<Description of malfunction>
•
EGR cooler outlet temperature cannot be correctly recognized.
2.
DTC set condition
(1)
DTC detection condition
•
Starter key is "ON".
•
The condition that fuel injection quantity is 40 mm
3
/sc.cyl or less remains for 10 seconds or more.
•
The battery voltage is in the range of 10 to 16 V.
•
The engine is stopped, or the engine speed remains at 500 r/min or more for 5 seconds or more.
(2)
Judgement criteria
•
Output of the sensor remains at 0.27 V or less (740
C {1364
F} or higher) for 3 seconds or longer.
3.
Reset condition
•
After restoration to normal condition
4.
Indication, warning or system control regulation when the DTC is set.
•
MIL: ON
•
SVS light: OFF
$XW (PC2S)
(E1)
X85
XZG
Z70
$XV
(PCR1)
(VC1)
(E2)
(PCR2)
(VC2)
Z72
XZH
(VC2)
(PCR2)
(E2)
(VC)
(PCR1)
(E1)
(PC1S)
XG2
Z6R
EBJ
EBH
EBN
EBM
EBL
EBK
J0L
J0M
(VC)
(PIM)
(E)
ZJP (E4)
X0G (PIM)
15mA
5mA
15mA
15mA
2mA
2mA
15mA
15mA
15mA
Common rail
pressure sensor
Boost pressure sensor
Engine ECU
Z2N
(E2)
X7U
(THG)
(THG)
X4A
EGR cooler outlet
temperature sensor
10mA
10mA
SHTS021270300481