![HIMA HIMatrix F3 AIO 8/4 01 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/hima/himatrix-f3-aio-8-4-01/himatrix-f3-aio-8-4-01_manual_2136589033.webp)
F3 AIO 8/4 01
4 Start-up
HI 800 161 E Rev. 2.00
Page 33 of 56
4.2
Configuration
The remote I/O can be configured using a programming tool, SILworX or ELOP II Factory.
Which programming tool should be used, depends on the revision status of the operating
system (firmware):
SILworX is required for CPU OS V7 and higher.
ELOP II Factory is required for CPU OS up to V6.x.
i
How to switch between operating systems is described in Chapter
Loading Operating Systems
of the system manual for compact systems (HI 800 141 E).
Observe the following points when configuring the module:
In SILworX, the
Transmitter Voltage[01]
system parameter must be assigned a global
variable. This global variable is used to set the value for the transmitter supply, see Table 29.
In ELOP II Factory, the
Transmitter Voltage[01] [USINT]
system signal must be assigned a
signal. This signal is used to set the value for the transmitter supply, see Table 33.
i
The transmitter supply must be configured even if it is not used.
4.3
Configuration with SILworX
In the Hardware Editor, the remote I/Os are represented like a base plate equipped with the
following modules:
Processor module (CPU)
Input module (AI 8)
Output module (AO 4)
Double-click the module to open the Detail View with the corresponding tabs. The tabs are used
to assign the global variables configured in the user program to the system variables of the
corresponding module.
4.3.1
Parameters and Error Codes for the Inputs and Outputs
The following tables specify the system parameters that can be read and set for the inputs and
outputs, including the corresponding error codes.
In the user program, the error codes can be read using the variables assigned within the logic.
The error codes can also be displayed in SILworX.
4.3.2
Analog Inputs F3 AIO 8/4 01
The following tables present the statuses and parameters for the input module (AI 8) in the
same order as given in the Hardware Editor.