1.7.1
PROFINET IO Device Firmware Versions 2.1 und 3.4
The PROFINET IO Device firmware was revised and expanded and is
available in version 3.4.x.x since June 2010. The PROFINET IO Device
firmware V3.4.x.x compared to V2.1.x.x has the following main changes:
•
IRT (Class 3 synchronized) is supported (only for netX 100/500)
•
ChannelInit is also supported now (V2.1.x.x supports only SystemReset)
•
The API was revised and is only compatible regarding cyclic data
exchange.
If you want to change to V3.4.x.x, then you can read in the
PROFINET IO
Device Migration Guide
which changes are necessary in the application
program to use version 3.4.x.x.
SYCON.net V1.210.x.x and V1.300.x.x can configure PROFINET IO Device
Firmware V2.1.x.x as well as V3.4.x.x.
The development of the PROFINET IO Device firmware V2.1.x.x will not be
continued and delivered.
On the Communication Solutions DVD are both versions V3.4.x.x and
V2.1.x.x available in the directory firmware.
PROFINET IO Device V3
(Directory on the DVD \ File)
PROFINET IO Device V2
(only on request)
Firmware
Firmware\CIFX\cifxpns.nxf cifxpns.nxf*
Header
API\Header\Firmware\PROFINET IO IRT RT Device V3 PROFINET IO RT Device V2
GSDML
DVD:\EDS\PROFINET\GSDML-V2.2-HILSCHER-CIFX
RE PNS-20110413xml
GSDML-V2.1-HILSCHER-CIFX RE PNS-20081210.xml
Protocol API
API\Protocol\PROFINET IO IRT RT Device V3\
PROFINET IO RT IRT Device Protocol API xx EN.pdf
Migration Guide: PROFINET IO Device - Version 2 to
Version 3 MG xx EN.pdf
PROFINET IO RT Device V2 Protocol API xx EN.pdf
Table 6: PROFINET IO Device Firmware Version 2.1 and 3.4, further Header, GSDML and
Protocol API
Important!
The PROFINET IO Device Firmware V2.1.x.x cannot be
configured by the netX Configuration Tool from version 1.0500.1.1564 on
any more, but only the PROFINET IO Device firmware versions from
V3.x.x.x on and higher. The firmware version 2.1.x.x can only be
configured with the netX Configuration Tool up to the Version
1.0500.1.1564.
2
For the PROFINET IO Device Firmware with V3.4.19.0 the
GSDML-V2.2-
HILSCHER-CIFX RE PNS-20110413.xml