Technical Data
103/145
PC Cards cifX PCI, PCIe, Low Profile PCIe | Installation, Operation and Hardware Description
DOC120204UM36EN | Revision 36 | English | 2012-10 | Released | Public
© Hilscher, 2008-2012
10.1.10 CIFX 50E-DP
Item
CIFX 50E-DP
System Interface
(Bus Type)
PCI Express, One Lane Port, according to [bus spec 2, Rev. 2.0] and [bus
spec 3], (refer to section
Overview on the Pin Assignment at the Bus
, page
95), transmission rate 2 GBit/s, 32-Bit width for the data access to the Dual-
Port Memory (DPM), or IO-DMA* (Direct Memory Access); *beginning from
Hardware Revision 5
Dual-Port Memory Size
64 KByte
Function
Communication interface with PCI Express and PROFIBUS interface
Communication
Determined by the loaded firmware
Protocols
PROFIBUS DP Master, PROFIBUS DP Slave, PROFIBUS MPI Device
Processor
netX 100
LEDs
SYS, COM; (refer also to chapter
LED Descriptions
, page 66).
Rotary Switch Slot Number
(Card ID)
To set the Slot Number (Card ID)
Configuration Software
SYCON.net (Master and Slave) or netX Configuration Tool (only Slave)
PROFIBUS Interface
DSub female Connector, 9 pin; Isolated RS-485 Interface;
(refer also to chapter
PROFIBUS Interface
page 88).
Supply Voltage
+3.3 V ±5 %/Typ. 800 mA
Dimensions (L x W x D)
Beginning with hardware revision 5: 120,0 x 86 x 18,5 mm;
[W = 86 mm, as with Rotary Switch Slot Number (Card ID)].
Operating Temperature
0 °C ... +55 °C
Environment
The device must be used in a pollution degree 2 environment.
UL Certification
The device is UL 508 certified (UL-File No E221530).
Table 96: Technical Data CIFX 50E-DP
10.1.11 CIFX 50E-CO
Item
CIFX 50E-CO
System Interface
(Bus Type)
PCI Express, One Lane Port, according to [bus spec 2, Rev. 2.0] and [bus
spec 3], (refer to section
Overview on the Pin Assignment at the Bus
,
page 95), transmission rate 2 GBit/s, 32-Bit width for the data access to the
Dual-Port Memory (DPM), or IO-DMA* (Direct Memory Access); *beginning
from Hardware Revision 4
Dual-Port Memory Size
64 KByte
Function
Communication interface with PCI Express and CANopen interface
Communication
Determined by the loaded firmware
Protocols
CANopen Master, CANopen Slave
Processor
netX 100
LEDs
SYS, CAN; (refer also to chapter
LED Descriptions
, page 66).
Rotary Switch Slot Number
(Card ID)
To set the Slot Number (Card ID)
Configuration Software
SYCON.net (Master and Slave) or netX Configuration Tool (only Slave)
CANopen Interface
DSub male Connector, 9 pin; Isolated ISO-11898 Interface;
(refer also to chapter
CANopen Interface
, page 88).
Supply Voltage
+3.3 V dc ±5 %/Typ. 800 mA
Dimensions (L x W x D)
Beginning with hardware revision 4: 120,0 x 86 x 18,5 mm;
[W = 86 mm, as with Rotary Switch Slot Number (Card ID)].
Operating Temperature
0 °C ... +55 °C
Environment
The device must be used in a pollution degree 2 environment.
UL Certification
The device is UL 508 certified (UL-File No E221530).
Table 97: Technical Data CIFX 50E-CO