Access Controller
·
User Manual
6
No.
DS-K2601-G
A10
OK
Indicator of Card Reader Control
Output (Valid Card Output)
A11
Wiegand Card Reader 1
GND
Grounding
A12
W0
Wiegand Head Read Data Input Data0
A13
W1
Wiegand Head Read Data Input Data1
A14
BZ
Card Reader Buzzer Control Output
A15
ERR
Indicator of Card Reader Control
Output (Invalid Card Output)
A16
OK
Indicator of Card Reader Control
Output (Valid Card Output)
B1
Arming Region Input
Z1
Arming Region Access Terminal 1
(Only for Linkage of Alarm Relay
Output)
B2
GND
Grounding
B3
Z2
Arming Region Access Terminal 2
(Only for Linkage of Alarm Relay
Output)
B4
Z3
Arming Region Access Terminal 3
(Only for Linkage of Alarm Relay
Output)
B5
GND
Grounding
B6
Z4
Arming Region Access Terminal 4
(Only for Linkage of Alarm Relay
Output)
B7
E-Lock
D1+
Door 1 Door Relay Input (Dry Contact)
B8
D1-
B9
Door Contact Input
S1
Door 1 Door Contact Detector Input
B10
GND
Grounding
B11
Door Open Button
B1
Door 1 Door Open Button Input
B12
GND
Grounding
C1
Power
+12V
DC12V Cathode
C2
GND
DC12V Grounding Input
C3
Battery
BAT+
DC12V Battery Cathode
C4
BAT-
DC12V Battery Anode
C5
485 Card Reader
RS 485A+
Card Reader RS485+ Access
C6
RS 485A-
Card Reader RS485- Access
C7
GND
Grounding
C8
RS 485B+
Card Reader RS485+
C9
RS 485B-
Card Reader RS485-
C10
GND
Grounding
C11
Access Controller RS485
Interface
RS 485C+
Uplink RS485+Communication
C12
RS 485C-
Uplink RS485-Communication
C13
GND
Grounding
Содержание DS-K2600-G Series
Страница 1: ...DS K2600 G Series Access Controller User Manual UD05678B...
Страница 27: ...Access Controller User Manual 18 4 4 Connecting the External Alarm Device 4 5 Door Button Wiring Diagram...
Страница 28: ...Access Controller User Manual 19 4 6 The Connection of Magnetics Detection 4 7 Connecting Power Supply...
Страница 30: ...Access Controller User Manual 21 4 9 Fire Alarm Module Wiring...
Страница 33: ...Access Controller User Manual 24...
Страница 125: ...Access Controller User Manual 116...