Access Controller
·
User Manual
98
4)
(Optional) Click
or
to change the rule order.
5)
(Optional) Select the rules in the Selected Rule list and click
to remove the rule from
the list on the right.
6)
Click
OK
to save the settings.
7)
In the Custom Wiegand tab, set the rule start bit, length, and the decimal digit.
8.
Click
Save
at the upper right corner of the interface to save the settings.
Notes:
By default, the device disables the custom wiegand function.
If the device enables the custom wiegand function, all wiegand interfaces in the device will
use the customized wiegand protocol.
Up to 5 custom wiegands can be set.
Up to 32 characters are allowed in the custom wiegand name.
Up to 80 bits are available in the total length.
The odd parity start bit, the odd parity length, the even parity start bit and the even parity
length range from 1 to 80 bit.
The start bit of the card ID, the manufacturer code, the site code, and the OEM should
range from 1 to 80 bit.
For details about the custom wiegand, see Appendix.
7.9
Searching Access Control Event
Purpose:
You can search the access control history events including device exception event, door event,
alarm input, and card reader event.
Click
icon and click Access Control Event tab to enter the following interface.
Содержание DS-K2600-G Series
Страница 1: ...DS K2600 G Series Access Controller User Manual UD05678B...
Страница 27: ...Access Controller User Manual 18 4 4 Connecting the External Alarm Device 4 5 Door Button Wiring Diagram...
Страница 28: ...Access Controller User Manual 19 4 6 The Connection of Magnetics Detection 4 7 Connecting Power Supply...
Страница 30: ...Access Controller User Manual 21 4 9 Fire Alarm Module Wiring...
Страница 33: ...Access Controller User Manual 24...
Страница 125: ...Access Controller User Manual 116...