7.3. Switching off the control system
• Switch off the control system with the on/off button .
If you are using the remote controller:
• Push the stop button on the controller and switch off the
control system.
• Disengage the PTO.
7.4. Emergency operation Valve-V200
EMERGENCY operation to bring the crane to transport position
Do like this:
On the main control valve:
DANGER
To operate the crane like this is HIGHLY DANGEROUS because during
emergency operation all crane security is disconnected.
Always go to/contact a HIAB service workshop when the seal wire has been
broken.
1. Engage the pump.
2. Break the security sealing on dump valve 1 (1) on the
main control valve.
3. Use a screw driver (or similar) and push the knob on
dump valve 1 (1).
4. Check that no unintended movements starts. If you get
unintended movements then release the knob and
contact HIAB service.
5. Push the dump valve button and turn 90 degrees until
it is blocked.
6. Operate the crane to transport position using the
levers on the main control valve.
1
Ending crane operation
HIAB K-HiPro 285-425 X4