CTC symbols
The order of the levers is customized.
• CTC mode, crane tip up/down ①
• CTC mode, crane tip out/in ②
• Activate manual control of the 1st boom in CTC mode ③
• Operate 1st boom up/down manually in CTC mode ④
4.12.5. Battery and battery charger XSDrive
Battery
A fully charged battery provides approximately 5-8 hours use (at 25 °C, 77 °F) and the voltage level
is approximately 8,4V. When the battery is about to wear out an indicator LED on the controller
burns steady red and the horn will sound twice. Push the stop button before changing the battery.
Note that the battery voltage remains between 7,6V and 7,5V for a long time. Therefore, the battery
voltage cannot be used to estimate remaining hours of use.
Battery charger
The battery charger is to be fitted in a protected
environment, preferably in the cab. Two batteries are
delivered with each unit, one of which can always be
placed in the charger.
LED (1) is lit continuously when the battery charger is
ready for use. Place the battery in the charger. LED (2)
flashes slowly during recharging and has a steady light
when the battery is fully charged.
Charging time
The normal charging time for a flat battery, is approximately 3 hours. Operating ambient temp:
Battery = 0° to + 45°C.
NOTE
A charged battery is a concentrated energy source. Never store a charged battery
in a toolbox or similar, where there is a risk of a short due to contact with metal
components. Used batteries should be taken care of according to the local
regulations.
The HiPro system
48
HIAB K-HiPro 285-425 X4