OLP stabiliser system [option]:
The centre display shows the symbol 100% and the symbol
for which stabiliser leg has overload (marked with an X).
Symbols shown on the display:
(1) Stabiliser extension in or not completely out. Stabiliser
leg set (the stabiliser leg reaches the minimum pressure to
the ground).
(2) Stabiliser extension out. Stabiliser leg not set.
(3) Stabiliser extension out. Stabiliser leg set.
(4) Stabiliser extension out. Stabiliser leg in OLP situation.
(5) Front left or right stabiliser leg in OLP situation.
In an OLP situation, symbol "x" is shown in every menu in
the centre display.
VSL-OLP [option]:
The centre display shows the symbol VSL. The 100%
symbol in the left display alternates with OLP for crane.
Move the levers to neutral and only operate permitted
(pressure reducing) functions.
6.4. To release OLP
If all functions have been blocked due to OLP it is possible to temporarily release OLP and operate
an appropriate crane function to correct the overload situation. OLP release is active in 5 second
intervals. After each 5 second interval of OLP release there is a wait before the release operation
can be activated again. The wait will increase in three steps: 30, 60 and maximum 90 seconds.
During each 5 second interval only one function at a time can be operated. Extension out cannot
be operated at all. The 5 second interval starts to count down as you move the lever.
1
2
3
4
5
VSL
CRANE 1
100%
During operation
78
HIAB K-HiPro 285-425 X4