15. Admit the new card to the Pensando Policy and Services Manager (PSM).
For more information, see the PSM Enterprise Edition User Guide.
Storage controller options
This server supports the following controllers:
• Embedded controllers
The embedded controller is enabled through UEFI System Utilities and configured using either System Utilities or the
HPE Smart Storage Administrator (Intelligent Provisioning).
For more information, see
• Type-p storage controllers
Type-p storage controllers install in a PCIe expansion slot.
For a complete list of supported storage controller models, see the server QuickSpecs on the Hewlett Packard Enterprise
website (
Installing a type-p controller
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove power from
the server by removing the power cord. The front panel Power On/Standby button does not shut off system power.
Portions of the power supply and some internal circuitry remain active until AC power is removed.
CAUTION: To prevent improper cooling or thermal damage, the server PCI slots must have an expansion slot blank
or an expansion board installed.
CAUTION: Hewlett Packard Enterprise recommends performing a backup of all server data before installing or
removing a controller or adapter.
Population guidelines
• Up to four internal cabled controllers can be installed in the primary riser cage.
• The butterfly riser supports only two internal cabled controllers in slots 15 and 16.
• No internal cabled controllers are supported in slots 8 through 14.
• There are no limitations on the number of externally cabled controllers.
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
• The components included with the hardware option kit
• T-10 Torx screwdriver
Before installing the controller, observe the following requirements:
Hardware options installation
117
Содержание HPE ProLiant DL580 Gen10
Страница 11: ...Eight bay SFF NVMe drive cage Six bay SFF HDD Two bay NVMe SSD Premium drive cage Component identification 11...
Страница 12: ...Two bay SFF Premium drive cage Front panel LEDs and buttons Power switch module Component identification 12...
Страница 106: ...Four processor configuration Hardware options installation 106...
Страница 161: ...Drive box 1 to butterfly riser cage Drive box 2 to primary riser cage 4 drive configuration Cabling 161...
Страница 163: ...Drive box 2 to 4 port mezzanine card Drive box 3 to primary 4 port riser Cabling 163...