4.
Remove the access panel (
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the
server in this manner results in improper airflow and improper cooling that can lead to thermal damage.
5.
6.
Remove the expansion slot blank from slot 5 (primary riser cage) or slot 15 (butterfly riser cage).
The primary PCIe riser cage is shown.
7.
Using the labels on each cable, connect the cables to the SAS expander.
8.
Install the 12G SAS expander card into expansion slot 5 or slot 15.
9.
Install the riser cage.
10. Using the labels on the cables to determine the correct connections, connect the cables from ports 3 and 4 of the
SAS expander card to the corresponding SAS controller in slot 6 or 16.
11. Connect the cables from the SAS expander card to the drive backplanes.