CAUTION: To prevent possible system malfunction and damage to the equipment, multiprocessor configurations must
contain processors with the same part number.
IMPORTANT: If installing a processor with a faster speed, update the system ROM before installing the processor.
IMPORTANT: Processor socket 1 must be populated at all times or the system does not function.
For optimum performance, Hewlett Packard Enterprise recommends:
• Use DIMMs that match the speed of the processor installed in the system.
• In a multiprocessor configuration, balance the total capacity of the DIMMs across the processors.
IMPORTANT: Existing HPE ProLiant and HPE Synergy Gen10 server products containing first-generation Intel Xeon
Scalable processors may not be upgraded to second-generation Intel Xeon Scalable processors at this time.
For more information, see the product QuickSpecs on the Hewlett Packard Enterprise website (
info/qs).
Prerequisites
Before installing this option, be sure that you have the following items:
• Processor or heatsink kit contents
• T-30 Torx screwdriver
Procedure
1.
2.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the system.
3.
Remove the system from the rack (
Remove the system from the rack).
4.
Place the system on a flat, level work surface.
5.
Remove the access panel (
6.
Remove the air baffle (
7.
Remove the dust cover from the processor socket you are going to upgrade.
8.
Install the processor heatsink assembly.
a. Using a T-30 Torx screwdriver, fully tighten each heatsink nut in the order indicated on the heatsink label (1 -2 -3 -4)
until it no longer turns.
Hardware options installation
94
Содержание Apollo 4200 Gen10
Страница 36: ...NVMe rear drive cage fan numbering Component identification 36...
Страница 51: ...Two bay SFF hot plug rear drive cage removal Six bay SFF NVMe drive cage removal Operations 51...
Страница 52: ...Six bay SFF rear drive cage SAS or SATA To replace the component reverse the removal procedure Operations 52...
Страница 134: ...Fan assembly cabling Item Description 1 Fan assembly power cable 2 Fan assembly signal cable Cabling 134...
Страница 135: ...Front panel cabling Item Description 1 Front I O cable 2 Front USB 2 0 cable Cabling 135...