• The system automatically sets all device numbers.
• If only one drive is used, install the drive in the drive bay with the lowest device number (
• Drives must be the same capacity to provide the greatest storage space efficiency when drives are grouped together into
the same drive array.
Installing a drive
CAUTION: Do not operate the system with any of the front or rear drive cage bays empty. To maintain proper airflow
and sufficient cooling, all drive bays in the front and rear cage must have a drive or a drive blank.
Procedure
1. If installed, remove the security bezel (Remove the bezel).
2. If you are installing a drive into the internal drive cage, extend the front drive cage from the chassis (Extend the front
drive cages out of the chassis).
3. Remove the drive blank:
• LFF drive blank
• SFF drive blank
4. Install the drive:
Hardware options installation
67