NOTE: The system ships with the same version programmed on each side of the ROM.
Safety and security benefits
When you flash the system ROM, the flashing mechanism writes over the backup ROM and saves the current ROM as a backup,
enabling you to switch easily to the alternate ROM version if the new ROM becomes corrupted for any reason. This feature
protects the existing ROM version, even if you experience a power failure while flashing the ROM.
Keeping the system current
Updating firmware or system ROM
To update firmware or system ROM, use one of the following methods:
• The
Firmware Update option in the System Utilities.
• The
fwupdate
command in the
Embedded UEFI Shell.
• Service Pack for ProLiant (SPP)
• HPE online flash components
• Moonshot Component Pack
Service Pack for ProLiant
SPP is a systems software and firmware solution delivered as a single ISO file download. This solution uses SUM as the
deployment tool and is tested and supports HPE ProLiant, HPE BladeSystem, HPE Synergy, and HPE Apollo servers and
infrastructure.
SPP, along with SUM and SUT, provides Smart Update system maintenance tools that systematically update HPE ProLiant,
HPE BladeSystem, HPE Synergy, and HPE Apollo servers and infrastructure.
SPP can be used in an online mode on a server running Windows, Linux, or VMware vSphere ESXi, or in an offline mode where
the server is booted to an operating system included in the ISO file.
The preferred method for downloading an SPP is using the SPP Custom Download at
https://www.hpe.com/servers/spp/
The SPP is also available for download from the SPP download page at
https://www.hpe.com/servers/spp/download.
Smart Update Manager
SUM is an innovative tool for maintaining and updating the firmware, drivers, and system software of HPE ProLiant, HPE
BladeSystem, HPE Synergy, and HPE Apollo servers, infrastructure, and associated options.
SUM identifies associated nodes you can update at the same time to avoid interdependency issues.
Key features of SUM include:
• Discovery engine that finds installed versions of hardware, firmware, and software on nodes.
• SUM deploys updates in the correct order and ensures that all dependencies are met before deploying an update.
• Interdependency checking.
• Automatic and step-by-step Localhost Guided Update process.
• Web browser-based user interface.
Software and configuration utilities
145
Содержание Apollo 4200 Gen10
Страница 36: ...NVMe rear drive cage fan numbering Component identification 36...
Страница 51: ...Two bay SFF hot plug rear drive cage removal Six bay SFF NVMe drive cage removal Operations 51...
Страница 52: ...Six bay SFF rear drive cage SAS or SATA To replace the component reverse the removal procedure Operations 52...
Страница 134: ...Fan assembly cabling Item Description 1 Fan assembly power cable 2 Fan assembly signal cable Cabling 134...
Страница 135: ...Front panel cabling Item Description 1 Front I O cable 2 Front USB 2 0 cable Cabling 135...