Troubleshooting
Error Messages
The message “Please check cover!” will appear on the screen when the lid is not closed
properly. Wait until the message disappears and re-start the cycle again by closing the lid
firmly.
Problem solving
Control panel is not
illuminated
Connect the machine to the power socket
Check / replace the main fuse
Check / replace the fuse of the control transformer
Control panel is on but no
activity after closing the lid
Check / replace the fuse of control transformer
Check / adjust / replace the lid switch
Check / replace the circuit board fuse
Insufficient end-vacuum
Check / adjust vacuum setting of the program
Check if extraction opening is not covered
Check level and/or contamination of the oil in the pump
Check / replace the oil exhaust filter
Check / replace the lid gasket
Vacuuming process is slow
Check if extraction opening is not covered
Check level and/or contamination of the oil in the pump
Check / replace the oil exhaust filter
Vacuum bag is not properly
sealed
Check / adjust sealing setting of the program
Check / replace the Teflon tape
Check / replace the silicone in the silicone holder
Check / clean the inside of the vacuum bag for contamination
Decrease the setting for gas flush (if activated)
Insufficient gas in the
vacuum bag
Check / open / replace the gas bottle
Check / adjust gas flush setting of the program
For all other problems please contact the supplier.