  To place a roll of labels in the machine. Pull the green levers on the side forwards 

and open the lid. Remove at least two labels from the backing foil. Push the roll 
carriers outside and place the roll between them. Then pull the dispenser down to 
create an opening. Now lead the label foil as shown in the picture. 

 

  Close the dispenser if the label foil is correctly placed. 

  Now close the lid and push the green button on top once. The printer now 

automatically goes to the next label. 

  When using a different length of label, you have to recalibrate the printer. The above 

steps are equal. Just hold the green button till the light under the button blinks twice. 
Now the sensors register the length of the new label.  

  For activating the printer and changing the setting, check the chapter ‘Settings’. 

It is not possible to change the type of font or font size of the printed text on the label. Using 
a label with a different size as the supplied label, might result in a situation where the printed 
text will be unreadable.  

The setting of the printer is based upon a label roll that has separate labels. The free space 
between two labels is used to determine the length of the label. Using a printer roll without 
these free spaces will not work before the printer settings have been changed. Please review 
the Printer manual. 

 

Содержание Lynx 32

Страница 1: ...User manual Lynx 42 Lynx 32 L ENG C...

Страница 2: ...2 All rights reserved No part of this publication may be reproduced by photocopy printing or in any other way without prior consent from Henkelman B V...

Страница 3: ...1st time 10 Machine functions 11 Function description 11 Guideline for function values 14 Function relations 16 Controlling the machine 17 Control panel overview 17 On off button 17 Step button right...

Страница 4: ...Oil Cleaning Program 30 Oil maintenance 30 Changing Oil Filling Up 30 Oil system overview 31 Oil types and amounts 32 Changing the oil exhaust filter 33 Filter housing types 33 Changing oil exhaust f...

Страница 5: ...ts authorized distributors In the case of malfunctions contact the supplier Always clean the lid with solvent free cleaning agents Solvents may damage the lid The machine must always be completely vol...

Страница 6: ...e overview Lynx 32 1 Lid 2 Seal bar 3 Gas flush nozzle if applicable 4 Lid lock 5 Control Panel 6 On off switch 7 USB port 8 Vacuum ventilation nozzle 9 Power socket 10 Gas bottle connector 11 Oil sig...

Страница 7: ...x 42 1 Lid 2 Seal bar 3 Gas flush nozzle Bag holder if applicable 4 Lid lock 5 Control Panel 6 On off switch 7 USB port 8 Vacuum ventilation nozzle 9 Power socket 10 Gas bottle connector 11 Oil sight...

Страница 8: ...When operating the machine in other ambient temperatures please contact the supplier for advice Connecting the machine Check that the voltage stated on the machine tag is the same as the mains voltag...

Страница 9: ...aforementioned gasses Accidents and or damage caused by using abovementioned gasses void all liability on the part of supplier as well as the guarantee The gas bottles must always be correctly secured...

Страница 10: ...l is delivered in a separate bottle 2 Press the on off switch 3 Select the desired program 4 Put the product in the vacuum bag and place it in the machine with the opening of the bag over the seal bar...

Страница 11: ...hPa This is the percentage or value of the pressure in the vacuum chamber related to the normal outside atmosphere of 1 bar 0 Optional the Gas Plus function can be programmed with an additional time...

Страница 12: ...t is possible to program a maximum of 5 steps Soft Air Herewith it is possible to allow the air from outside to slowly enter the chamber so the vacuum bag will shape itself slowly around the product a...

Страница 13: ...ntainer related to the normal outside atmosphere of 1 bar Menu Menu is used the change machine setting such as language printing options The functions H2O and H2O Plus Gas and Gas plus 1 2 Cut off sea...

Страница 14: ...scape from the product Gas 2 700 mbar 0 70 The two main reasons for gas flushing are first to increase shelf life by the chemical reaction between gas and the product Secondly to protect fragile produ...

Страница 15: ...he bag The best way to determine the right time is trial and error Sequential Vacuum Holding time 2 700 mbar 30 99 8 0 1 5 0 sec In case the Vacuum Plus time is not effective enough to allow entrapped...

Страница 16: ...gram Vacuum Vacuum Plus Red Meat H 2 O H 2 O Plus Sequential Vacuum Gas Gas Plus Seal 1 2 Cut off seal Soft air Printer Vacuum Vacuum Plus Red Meat H2O H2O Plus Sequential Vacuum Gas Gas Plus Seal 1 2...

Страница 17: ...cycle will skip all functions and terminate the cycle Screen The screen has four possible modes Startup mode it shows the current date and time during the startup of the machine It also displays the...

Страница 18: ...ure on the right These names will be used for the navigation description in the next section Viewing machine programs Users can view machine programs and the active functions in the navigation mode Th...

Страница 19: ...layed in color tone When it is inactive it is displayed in soft tone Both tones are illustrated in the figure on the right If the Plus functions are activated the illustration is displayed in color If...

Страница 20: ...chine settings and all functions settings An authorization code is requested when the enter button is pressed while the menu icon is selected in the navigation mode When the owner s code has been put...

Страница 21: ...to Numeric Increase the value Decrease the value Character Get a lowercase alphabet Get numbers and a capital alphabet Go to the previous next character On off Change mode Change mode Multiple choice...

Страница 22: ...22 Setting overview The sitemap below gives an overview of all the settings of the machine The sitemap shows all possible settings for all functions...

Страница 23: ...operating the label printer Turn off the vacuum machine and connect the printer via the USB cable to the machine Connect the power cable of the printer Turn the vacuum machine and the printer on USB...

Страница 24: ...ter The above steps are equal Just hold the green button till the light under the button blinks twice Now the sensors register the length of the new label For activating the printer and changing the s...

Страница 25: ...le of the machine as shown Connect the other side of the external vacuum hose to the container that needs to be vacuumed Make sure this container is capable of resisting and holding a vacuum Use the c...

Страница 26: ...act your supplier for this software Creating programs labels with the Lynx software programming tool Installing the Lynx software programming tool Create a folder on the C drive of your PC and name it...

Страница 27: ...firm the existing programs and labels will be overwritten by the data that have been programmed on the PC Note Never change the txt files by opening them in notepad or any other program This will resu...

Страница 28: ...onally service it every 6 months For normal use of the machine complete servicing once a year should be sufficient depending on location environment and products If there are doubts about the maintena...

Страница 29: ...ire if the seal quality is no longer sufficient or if the Teflon tape sealing wire is no longer tight and straight on the sealing bar See instructions Inspect the lid gasket and replace it when the ga...

Страница 30: ...tomatically after closing the lid If necessary the program can be interrupted at any time using the STOP key Use the conditioning program at least once a week to enhance correct and long lasting pump...

Страница 31: ...nt the oil drain plug Filling up oil After draining or when the oil level is low oil needs to be filled up The oil fill plug must be removed The pump can now be filled with oil Take care to fill with...

Страница 32: ...e is operated is also important for the type of oil If the machine is used outside normal specifications regarding ambient temperature contact the supplier See amounts and types with related ambient t...

Страница 33: ...the pump absorb and filter oil vapours The filter should be replaced after 12 to 18 months When the filters are saturated it is no longer possible to achieve maximum vacuum Filter housing types Remov...

Страница 34: ...34 Lynx 42 To create access for the filter to be removed the gas spring bracket needs to be disassembled as shown...

Страница 35: ...lace a new filter and screw it tight Please note that an O ring should be placed at the exhaust filter inlet Replace filter 16 m3 h Lynx 42 Unscrew the oil exhaust filter cover and remove the filter b...

Страница 36: ...size of the sealing beam plus about 15 cm 6 inches First attach one side of the wire at a side of the seal bar and screw it tight Now attach the other side of the wire at the other side of the seal ba...

Страница 37: ...ve the old silicone rubber from the holder Cut a new piece of silicone rubber to the same size as the old one The same size is very important too short or too long will cause problems with sealing Pla...

Страница 38: ...e the lid gasket at least once every 6 months Remove the old gasket rubber from the holder Cut a new piece of rubber of the same size as the old one When the lid rubber is too short or too long it can...

Страница 39: ...just vacuum setting of the program Check if extraction opening is not covered Check level and or contamination of the oil in the pump Check replace the oil exhaust filter Check replace the lid gasket...

Страница 40: ...upplied or by the unsuitability of it for the goal for which the other party purchased it Warranty Subject to the following limitations the warranty period for products supplied by Henkelman is at lea...

Страница 41: ...ded from the warranty 7 If we replace parts in compliance with the obligations of this warranty then the replaced parts become our property The stipulations of the warranty and liability are part of t...

Страница 42: ...42 Electrical diagram Lynx 32 42 main circuit diagram...

Страница 43: ...43 Electrical diagram Lynx 32 42 control diagram...

Страница 44: ...Neutral PE Ground connection Overload devices Fuse main entrance F1 F2 Part number 0232014 Specification 10 Amp Slow Size 5 x 20 mm Fuse seal transformer F4 Part number 0232027 Specification 3 15 Amp...

Страница 45: ...Tb 1 Part number 0223011 Input 220 230 Volt Capacity 60 Va Output 1 24 Volt Output 2 9 Volt ED 100 Seal bar Used Seal bar R1 Connection Stand alone Contactors Pump K1 Part number 0221007 Seal K2 Part...

Страница 46: ...N Neutral PE Ground connection Overload devices Fuse main entrance F1 F2 Part number 0232014 Specification 10 Amp Slow Size 5 x 20 mm Fuse seal transformer F4 Part number 0232018 Specification 5 Amp S...

Страница 47: ...Tb 1 Part number 0223011 Input 220 230 Volt Capacity 60 Va Output 1 24 Volt Output 2 9 Volt ED 100 Seal bar Used Seal bar R1 Connection Stand alone Contactors Pump K1 Part number 0221007 Seal K2 Part...

Страница 48: ...s P O Box 2117 5202 CC s Hertogenbosch The Netherlands Address Titaniumlaan 9 5221 CK s Hertogenbosch The Netherlands Tel 31 0 73 621 3671 Fax 31 0 73 622 1318 E mail info henkelman com Information ww...

Отзывы: