13
Press the “Function” key to enter into “bypass zone” setup mode
and display the following information:
Hour: Press <
Minute: Press >
Function 6
key to set hour
key to set minute
Set bypass
zone
In this mode, press “<” key to select the zone and press “>” key to
select bypass/unbypass mode. “00” means this zone is bypassed,
while “01” means this zone is unbypassed.
It should be noted that, whether the defense zone is a common zone or
an emergency zone, all alarm information won’t be received if the
zone is bypassed by the wireless receiving host.
The factory-set mode is that all defense zones are bypassed.
When the host learns code with detectors in certain defense zone, all
defense zones will be automatically unbypassed.
It is recommended to apply this function when any failure occurs in
defense zones. Once the failure is recovered, the host shall be set in
bypass mode in time so as not to avoid loss of any alarm information
in defense zones.
To prevent user from forgetting to restore the bypass-zone, the
host will automatically reset all zone to original value after power
break, so the alarm will be available again.
When sensors alarms frequency or not in good condition,in this
status,press function key enable bypass operation,so as to testing
whether the sensor is right or wrong.
(7)
(7)
(7)
(7) How
How
How
How to
to
to
to Inquire
Inquire
Inquire
Inquire Records
Records
Records
Records
Press the “Function” key to enter into “Log Inquiry” setup
mode and display the following information: