12
Press the “Function” key to enter into “The second group of
automatic power off time” setup mode and display the following
information:
Hour: Press <
Minute: Press >
Function 5
key to set hour
key to set minute
Set the second
group of power
off time
This mode, press “<” or “>” key to adjust the second group of
automatic power off time. After setup is completed, press the “Reset”
key to exit setup mode or press the “Function” key to set “bypass
zone”. The above figure shows that the second group of automatic
power off time is set at 8:00. For example, if a company begins
operating at 8:00 a.m., the check-out time is 12:00 noon, the check-in
time is 14:00 p.m. and the check out time is 18:00 p.m., the power-on
/power-off time of the wireless receiving host should be set as
follows:
The first group of power-on time is 12:00 noon, while the first
group of power-off time is 14:00 p.m.
The second group of power-on time is 18:00 p.m., the second group of
power-off time is 8:00 a.m.
It is recommended to reserve some time for employees to check
in ahead of schedule and stop off after check out so as not to cause
unnecessary alarms.
If you want the wireless receiving host to guard continuously for
24 hours per day, set the same time for any groups of “auto power on
time” and two groups of “automatic power off time”, e.g., set
automatic power on time and automatic power off time at “12:00”.
The factory-set mode is 24-hour continuous alert.