1.4 COMPONENT CHECK LIST
Within the Electromax Solar packaging the following components are supplied. Please check
that all parts are available before commencing installation.
• Electromax Solar
• Cold water combination valve
• Programmable room thermostat
• Immersion heater key spanner
• Hose connection adaptor for primary system drain valve
• Set of cable entry glands and blanking plugs (5 x 20mm, 1 x 25.4mm)
• Installation manual
• User instructions
• Fitting template
Warranty card
•
Divertor valve ( East/West models only )
•
2.0 TECHNICAL SPECIFICATIONS
2.1 GENERAL
Capacity (Total)
185 litre
220 litre
250 litre
Capacity (Solar)
65 litre
75 litre
80 litre
Weight (Empty)
94kg
105.5kg
112kg
Weight (Full)
279kg
325.5kg
362kg
Height
1580mm
1800mm
1990mm
Width
550mm
550mm
550mm
Depth
600mm
600mm
600mm
2.2 DHW CYLINDER
Rated pressure
0.6 MPa (6 bar)
Operating pressure
0.35 MPa (3.5bar)
Supply pressure
0.15 MPa min (1.5bar) – 1.6 MPa max (16bar) max at
PRV
Temp’ & pressure relief valve
1.0 MPa (10bar) / 90ºC
Pressure reducing valve
0.35 MPa (3.5bar)
Expansion relief valve
0.6 MPa (6bar) Fitted in Cold Water Combination Valve
Expansion vessel capacity
18 litre
Expansion vessel pre charge
0.35 MPa (3.5bar)
Check Valve
Fitted in Cold Water Combination Valve
Strainer
Fitted in Cold Water Combination Valve
Coil heat exchanger
Stainless Steel tube, Ø25mm, 1.1m² surface area
Lower immersion heater
3kW 825 alloy sheathed element (curved)
Upper immersion heater
3kW 825 alloy sheathed element (straight)
Thermostatic control
10 – 70°C rod type thermostats
Over temperature Control
85ºC manually re-settable double pole cut out