2.3 SOLAR CONTROLLER & SOLAR PRIMARY CIRCUIT
Rated pressure
1.0 MPa (10bar)
Operating pressure
0.2 – 0.4 MPa (2 - 4bar)
Pressure relief valve
0.6 MPa (6 bar)
Expansion vessel capacity
24 litres (supplied separately)
Expansion vessel pre charge
0.35 MPa ( 3.5bar) (supplied separately)
Flow meter
2 – 15 litre/min
Air vent
Manual type, fitted
Check valves
x2 fitted
Circulating pump
Grundfos UPS 15-50
Heat transfer fluid
Glycol / Water 40/60 mix (supplied separately)
Thermostatic control
Electronic controller
Over temperature control
85ºC manually re-settable double pole cut out
2.4 ELECTRIC BOILER & CENTRAL HEATING PRIMARY CIRCUIT
Rated pressure
0.3 MPa (3bar)
Operating pressure
0.1 MPa (1bar)
Pressure relief valve
0.3 MPa (3bar)
Expansion vessel capacity
12 litres
Expansion vessel pre charge
0.1 MPa (1bar)
Automatic bypass valve `
0.05 MPa (0.5bar)
Automatic air vent
Fitted
Circulating pump
Grundfos UPS 15-50
Electric boiler
9kW Electric flow type
2.5 CYLINDER PERFORMANCE
TABEL 01:
MODEL
AUXILIARY
VOLUME
HEAT UP TIME
- AUX (MINS)
HEAT UP TIME -
BOOST (MINS)
STANDING HEATLOSS
kWhr/24hr
185
120
126
60
1.76
220
145
152
60
1.73
250
170
178
60
1.70
Heat up time is based on raising the auxillary volume from 15ºC to 60ºC using the lower 3kW
immersion heater.
Boost Volume = 57 Litres
Heating times using solar primary circuit will be variable as they will depend on the amount of
solar radiation, sunshine hours, collector panel type, size and orientation.