83
Inadequate Baseboard.
When a water-to-water
heat exchanger is
installed, a temp drop
of 20-30° across heat
exchanger may be
experienced.
Contact your
Local Dealer.
not enough
domestic hot
water.
Hot water heater
is too small.
Sidearm exchanger
needs to have a pump
installed.
Refer to
“installation Manual.”
Somewhere in the
domestic water system
of the house, the hot and
the cold can mix, (as in a
single faucet outlet) and
the resulting mixed warm
water is being sent to the
hotwater taps instead of
pure hotwater
Contact your
Local Dealer
.
Manifold not balanced
properly. One appliance
getting more than its
share of the total flow of
hot water.
Balance the system by
adjusting the flow of
water to the different
heating appliances.
Refer to
“installation Manual.”
Outdoor furnace water
temperature is not
consistently between
145 and 185 degrees
Fahrenheit.
Refer to
“installation Manual”
Over time, (approx. five
years) with some water
conditions, the sidearm
will clog up with scale
(lime) and restrict or shut
off the flow completely
through the sidearm.
Refer to
“installation Manual.”
Improper hook up of the
sidearm exchanger.
Refer to
“installation Manual.”
Water in auger
tube.
Condensation formation
on cooler steel.
Maintain constant
firebox temperature.
Refer to
“ash auger tube.”
PrOBLeM
cause
sOLutiOn
PrOceDure