77
Too much supply water
going to certain heating
appliances.
Adjust water flow.
Contact your
Local Dealer
.
Outdoor temperatures
are warmer and supply
controls have not been
adjusted.
Adjust water flow.
Contact your
Local Dealer
.
High limit switch set too
low.
Adjust setting.
Refer to
“electrical (high Water
temperature safety shutoff
control).”
creosote
build-up.
Air leakage around Door.
Replace Door Gasket.
Refer to
“Firebox Door Gasket.”
Firebox receiving air
somewhere when
fans are off.
Check all seals
for air leaks.
Run a smoke check.
Refer to
“checking for air Leaks.”
Fire is not burning hot.
Check type of wood
burning and if blowers
working properly.
Refer to
“types of Wood,
combustion air Blower /
Flipper assembly”
Burning high surface
area wood (small pieces).
Add larger pieces
of wood.
Refer to
“types of Wood.”
Air flow is not sufficient
for the type of fuel.
Check and clean fan
blades. Check and
clean flipper assembly.
Refer to
“combustion air Blower /
Flipper assembly”
Ashes in Air Box(s).
Clean Air Box(s).
Refer to
“air Box.”
Chimney Plugged.
Clean Chimney.
Refer to
“chimney stub.”
Burning wet wood.
Add dryer wood as fuel.
Refer to
“types of Wood.”
Burning unseasoned
wood.
Add seasoned
wood to your fuel.
Refer to
“types of Wood.”
PrOBLeM
cause
sOLutiOn
PrOceDure
Содержание Response 200 SSRII
Страница 1: ...Operations And Maintenance Manual...
Страница 3: ...Outdoor Furnaces TM THE save these instructions...
Страница 12: ...5 HEATMOR Stainless Steel RESPONSE Outdoor Furnace Model Chapter 1 Model 200 SSRII...
Страница 93: ...Outdoor Furnaces...