73
Base leaks air.
Reseal Base.
Refer to
“caulking around the Firebox
Base.”
Electronic Controller
malfunction.
Replace Electronic
Controller.
Refer to
“electrical (
Electronic
Controller
)”
Water Level is Low.
Add Water.
Refer to
“Filling the heatMOr™
Outdoor Furnace initially with
Water.”
Creosote buildup on
firebox doorframe
causing improper door
seal.
Remove creosote from
doorframe.
Refer to
“Firedoor Frame”
Flipper assembly plate
not tight.
Tighten thumb nuts and
ensure a tight seal is
established.
Refer to
“steps to Maintain your
Blower and Flipper assembly”
Wrong type of sand or
not enough sand.
Remove and replace or
add sand.
Refer to
“sand (Firebox and other
components).”
Too little heat draw off
HEATMOR™.
Consult Dealer.
Contact your
Local Dealer
.
Circulating Pump not
Functioning.
Replace Pump.
Contact your
Local Dealer
.
no heat in
Building
Fire Out.
Light Fire.
Refer to
“Lighting your heatmor.”
Water level low.
Add Water.
Refer to
“Water Level Maintenance.”
Power loss.
Check Power Source.
Refer to
“electrical supply.”
Pump malfunction.
Replace Pump or
Cartridge.
Contact your
Local Dealer
.
PrOBLeM
cause
sOLutiOn
PrOceDure
Содержание Response 200 SSRII
Страница 1: ...Operations And Maintenance Manual...
Страница 3: ...Outdoor Furnaces TM THE save these instructions...
Страница 12: ...5 HEATMOR Stainless Steel RESPONSE Outdoor Furnace Model Chapter 1 Model 200 SSRII...
Страница 93: ...Outdoor Furnaces...