Section 5-3
17
MLSM2003-09-03
Procedure I
- Spark Module
Step 1: Disconnect power supply to
range. Pull range away from wall
and remove backguard held by 3
screws and washers. See Proce-
dure A Step 1.
Step 2: Prop Top Up. See Proce-
dure P.
Step 3: Disconnect screw holding
spark module to top and gently drop
down.
Step 4: Test wiring and connections
to spark module, particularly black,
white and green wires to ensure
they are tightly connected.
Step 4: There should be no conti-
nuity across any of the correspond-
ing terminals from one side of the
module to the other. If any show
continuity, replace spark module.
Step 5: To replace faulty spark
module, remove one wire at a time
from old module and transfer to
new module in the exact same
terminals as the original. Please
ensure quick connect leads are
properly and fully inserted into the
spark module spades (use pliers if
needed).
Step 6: Spark modules are held in
place by velcro.
Step 7: Test wiring from spark
module to ignition switches for
continuity and/or wires to elec-
trodes. Replace as needed.
IMPORTANT: ALL GAS WORK TO
BE PERFORMED BY A QUALIFIED
GAS TECHNICIAN.